![](http://p.yzimgs.com/global/12541/zh-cn/1669965188366.jpg)
- 盧森堡ROTAREX羅達(dá)萊克斯滅火系...
- 意大利GM SISTEMI火花探測及...
- 西班牙ADIX安迪克斯抑制爆炸系統(tǒng)
- 備盈倍BS&B防爆**系統(tǒng)
- 賀爾碧格Newson Gale防爆靜...
- 賀爾碧格hoerbiger防爆**系...
- 意大利Aircom愛科粉塵防爆設(shè)備
- 法國Stif斯緹福粉塵防爆設(shè)備
- 西班牙Adix安迪克斯隔爆閥抑制系統(tǒng)...
- 瑞士Rico瑞科爆炸隔離閥
- 意大利Control logic康洛...
- 意大利Control logic康洛...
- 意大利科恩除塵和防爆產(chǎn)品
- 美國Argus火花和金屬探測以及回收...
- 美國Edwards愛德華消防報(bào)警系統(tǒng)
- 美國Kidde凱德廚房滅火和空氣采樣...
- 美國Marioff HI-FOG高壓...
- 挪威納斯克激光氣體分析儀
- 德國Rembe認(rèn)必泄壓爆破片及隔離塵...
- 英國Amal阻火器
- 英國Marvac呼吸閥和緊急泄放閥以...
- 英國Marston防爆板和爆破片
- 美國ZOOK防爆板
- 瑞士Rico-Ventex隔爆閥
- 德國GreCon格雷康火花探測器以及...
- 德國Eltex埃爾特克斯防爆靜電接地...
- 美國迪康氣體檢測設(shè)備
- 美國PAC實(shí)驗(yàn)室和在線分析儀器
- 奧德姆/安姆特儀器產(chǎn)品
- 美盛環(huán)境監(jiān)測行業(yè)成套系統(tǒng)工程
- 美盛流體污染控制,過濾,分離凈化產(chǎn)品
- 美國Norman不銹鋼高壓過濾器
- 美國施羅德過濾器以及過濾系統(tǒng)
- 韓國杜科給水設(shè)備以及泵系統(tǒng)
- 美國Cameron卡麥龍過程控制和閥...
- 美國BARTON測量儀器儀表
- 美國NUFLO儀表產(chǎn)品
- 美國clif mock采樣設(shè)備和系統(tǒng)
- Caldon超聲波技術(shù)產(chǎn)品
- 美國Cameron/Barton卡麥...
- 美國Pentail濱特爾油液凈化設(shè)備...
- 韓國雷尊泰克REZONTECH火焰探...
- 韓國CSA Bestouch火焰探測...
- 科馬特泰克色譜技術(shù)產(chǎn)品
- 英國愛丁堡Edinburgh ins...
- 歐美Cerex/AquaRead等進(jìn)...
- 歐文凱利自控閥設(shè)備
- 德爾格Draeger**檢測設(shè)備
- 美國Det-tronics火焰探測器...
- 泵閥控制
- 美國Honeywell生命**產(chǎn)品
- 密析爾濕度和露點(diǎn)儀表
- 美國TIF公司鹵素檢漏儀
- 美國Teledyne Analyti...
- 美國泰科SCOTT健康和**
- 日本日置HIOKI電測產(chǎn)品
- 英國梅克羅尼(MICRONICS)超...
- 美國AII氧分析儀
- 美國Raytek紅外測溫儀
- 美國Fike火災(zāi),爆炸和卸壓產(chǎn)品
美國采樣系統(tǒng)公司Portable Cooling Water Sampler便攜式冷卻水取樣器
Portable Cooling Water Sampler
One difficult measurement to make in the domain of emissions control is that of fugitive volatile material, usually hydro carbonaceous, escaping from cooling tower water. Such measurements are necessary not only to allow plants to conform to laws limiting such emissions but also because sudden appearances of some materials in the cooling tower water are sometimes indicative of process leaks. The root of the analytical problem is that it is difficult to sample water in the field then to analyze it in the laboratory without some loss of the volatile material. Compounding the problem is the fact that the measurement of interest is the amount of material that volatilizes while the water is in the cooling tower. This measurement may not necessarily coincide with the total carbon in the water since some of it may be nonvolatile. Described herein is a sampling device, built specifically for use in the field, that can measure the volatile organic carbon content of cooling tower water.
Description:
The main vessel is a thick walled glass pipe thirty-six inches in length and three inches in diameter. It is packed by the end user to a depth of twenty six inches with 1/4" beryl saddles. All the lines to and from the main vessel are 1/4" stainless steel tubing, except 1/4" PFA tubing joining dryer and Erlenmeyer flask. The ends of the main vessel are sealed with threaded Teflon stoppers of the appropriate size. Gas exiting the main tube is passed through a glass tube, six inches long and one inch in diameter, packed with indicating Drierite furnished by the end user. This attachment dehumidifies the air stream with little or no absorption of hydrocarbon. The dried air the flows into a 250ml Erlenmeyer flask into which the probe of a detector (TLV Sniffer, Bacharach Instrument Company) has been sealed. Excess air not sucked into the Sniffer probe is vented through a bubbler which serves to indicate that such sufficient flow has been established. Water and air are metered into the system through rotometers.
Operation:
Before each series of runs, the Sniffer is calibrated by having a commercially available air-hydrocarbon mixture of know composition pass first through the drying tube then into the flask housing the probe where it is analyzed. Best results are obtained when the Sniffer has been allowed to warm up at least thirty minutes prior to calibration. Periodically the rotometers used to measure the air and water flow should be recalibrated. The air rotometer is calibrated on the volume of air delivered at ambient temperature and pressure, and the water rotometer is calibrated on water volume at ambient temperature. The ultimate accuracy of measurements made by this apparatus depends on the accuracy of these calibrations.
The initially empty apparatus is filled by having cooling tower water fed to it at a measured rate until the packing is just submerged. At that time the drain valve is opened just enough to maintain that water level. Then air from either a cylinder or a portable pump is bubbled through the packing from the bottom at a measured rate. In practice, we found that an air : water volume ration of 20:1 gives the best results. Since the Sniffer requires 2500 ml of air per minute, we routinely set the air flow slightly above 2500 ml per minute and the water flow at 125 ml per minute.
The Sniffer is read after the air and water streams have flowed at least ten minutes. The concentration of hydrocarbon in the water is calculated according to Equation 1:C=MPbc/RTa
C = weight ppm of hydrocarbon in the cooling water
M = molecular weight of the hydrocarbon, g/mol
P = pressure of air in the main tube in the atmospheres
a = water flow, ml/min
b = air flow, ml/min
c = volume ppm of hydrocarbon in the air (Sniffer reading)
R = 82.054 ml-atm/mol-K
T = temperature in kelvins
If M is not known precisely, or if the volatile material is a mixture, a convenient number can be substituted to yield reasonable results.