SaddleMount流形和隔離閥安裝系統(tǒng)
安德森格林伍德SaddleMount已經(jīng)開發(fā)出來,克服了傳統(tǒng)發(fā)射機(jī)/是與多方面的沖動線路連接裝置有關(guān)的問題。傳統(tǒng)的遠(yuǎn)程安裝的DP變送器/有多種設(shè)施被沖線**次使用前40年以上,允許技術(shù)人員進(jìn)入發(fā)射器,需要定期校準(zhǔn)和持續(xù)維護(hù)。發(fā)射機(jī)技術(shù)已大大提高,今天的高性能發(fā)射機(jī)需要較少的維護(hù)和校準(zhǔn)之間更長的時間。
The Anderson Greenwood SaddleMount has been developed to overcome the problems associated with traditional transmitter/manifold installations that are connected with impulse lines. Traditional remote mounted DP transmitter/manifold installations with impulse lines were first used over 40 years ago to allow technicians access to transmitters that required regular calibration and continuous maintenance. Transmitter technology has been significantly increased, and today’s high performance transmitters require less maintenance, and longer periods between calibrations.
Due to the problems associated with impulse lines, NPT screwed connections and resulting high maintenance costs, many leading companies are mandating that DP transmitter/manifold assemblies are mounted directly onto the orifice flange, negating the use of impulse line pipe work. Installing high accuracy DP Transmitters and Manifolds at the end of long impulse lines can prove to be a false economy.
Features & Benefits:
Anderson Greenwood developed the SaddleMount to provide a compact, leak free and safe modular system with:
- Rigid connection to the orifice flange
- High performance isolation/block valve module
- Choice of instrument modules
- No impulse lines or brackets
Specifications
Materials: 316 SS
Seats: Soft and Hard
Connections: Threaded and Socket Weld
Orifice Sizes: 3/8” [10 mm] bore
Pressure (max): 6,000 psi
Temperature (max): 500°F [260°C]